Hukseflux LP02 Pyranometer

Recommended for financeable resource assessment campaigns, the Hukseflux LP02 is a solar radiation sensor that is compliant with second class criteria from the ISO 9060 standard.

Product Configurations

Hukseflux LP02 Pyranometer

#6889



Details

This thermopile-based sensor measures global horizontal irradiance and has a spectrally flat response across the full solar spectrum. The LP02 generates a small voltage signal that is proportional to the solar radiation flux, expressed in W/m2.

The LP02 is compatible with the SymphoniePLUS®3 Data Logger and SymphoniePRO® Data Logger when equipped with a Symphonie® SCM Card (SCM #6646, used with SymphoniePLUS3 or older) or Pro Signal Conditioning Module (P-SCM #9128, used with SymphoniePRO).

This kit includes a calibration certificate and 5 m (16.4') cable.

Specifications

  Hukseflux LP02 Pyranometer (#6889)
Description
Sensor type Thermopile solar radiation sensor; ISO 9060 ‘Second Class’ compliant
Applications
  • Solar resource assessment and monitoring
  • Meteorological studies
  • Environmental monitoring
Sensor range 0 W/m2 to 2000 W/m2
Spectral range 305 nm to 2800 nm
Instrument compatibility
  • RNRG Symphonie loggers with Thermopile SCM (#6646)
  • Logger measurement range 0 W/m2 to 1500W/m2
Output signal
Signal type Microvolt proportional to total solar radiation
Transfer function Included on calibration certificate; for use with RNRG Symphonie see application note "Using Thermopile Pyranometers on Symphonie Loggers"
Accuracy Second Class per ISO 9060
Calibration Calibration sheet included with each sensor defines output in microvolts per Watt/square meter; traceable to World Radiometric Reference (WRR)
Calibration uncertainty < 1.8% (k=2) as specified by Hukseflux
Output signal range -0.1 mV to + 50 mV
Drift Less than 1% per year
Power requirements
Power Required Zero (passive sensor)
Installation
Mounting Mounts to tower with RNRG tower top mounting platform (9104) or side mounting boom (6772) (plane of array capable)
Tools required
  • 5/32 inch (4 mm) Hex Key
  • 5/16 inch (8 mm) wrench or nut driver
  • #2 phillips screwdriver
Environmental
Operating temperature range -40 °C to 80 °C (-40 °F to 176 °F)
Operating humidity range 0 to 100%
Physical
Connections Bare wire leads from cable connect directly to logger
see also logger user's manual for wiring diagram
Cable length 5 m (16.4 feet)
Weight 0.30 kg (0.66 lbs)
Dimensions 85 mm X 60 mm (3.3 inches X 2.4 inches)
Materials
Cable Shielded 2 conductor
Detector Thermopile
Enclosure IP67 weatherproof anodized aluminum enclosure and stainless steel hardware

Accessories